5.4.2 Cleaning the Rollers
CAUTION
NEVER use a sharp object to clean the Rollers.
Rollers contaminated with grit, label adhesive, or ink can cause a reduction in print quality. Label
tracking can also be affected. In extreme cases, labels may wrap the rollers. To prevent problems, clean
the rollers as follows:
1. Turn ‘Off’ and unplug the printer. Raise the access cover.
2. Raise the Head Lift Lever. Lower the Peel Assembly Release Lever. Remove media and ribbon.
3. Using a cotton swab dampened with isopropyl alcohol, clean the Rollers. Rotate each roller, wiping
and repeating until the entire roller is clean.
4. After allowing the Rollers to dry, replace ribbon and media. Close the Peel Assembly and lower the
Head Lift Lever into the locked position.
5. Close the access cover. Plug in and turn ‘On’ the printer. This completes the cleaning procedure.
Feed several labels to normalize media tracking.
Rollers
Peel Assembly
Peel Assembly Release Lever
Head Lift Lever