A-Class Mark II 43
Printer Options (continued)
Menu Item Details
LOCK AFTER WRITE
Allows the tag to be locked after programming, where:
ENABLED
Locks the tag.
DISABLED
Does not lock the tag.
RETRY ATTEMPTS
Sets the number of retry attempts, where:
(0 - 9)
3
Is the retry count before a fault is declared.
PERFORM CALIBRATION
Allows the printer to establish the tag to transducer
distance and nominal power setting, where:
YES
Initiates the process; CALIBRATING RFID will be
displayed as media is scanned for the tag location and
power, followed by TOF positioning and the
operational results where, if successful, the database
parameters will be updated.
NO
Exits the menu item without calibration.
SET DEFAULTS
Allows the RFID default values to be restored, where:
YES
Restores the default settings.
NO
Exits the menu item without changing the current
settings.